GC-32 GPIO CONTROLLER
Programming Manual
Revision History
05/09/12 First release
07/26/12 Added Table of Contents and product front & rear view
OVERVIEW................................................................................ 1
FRONT VIEW............................................................................. 2
REAR VIEW ............................................................................... 2
DEFAULT SETTINGS .................................................................. 2
PROTOCOL DESCRIPTION ......................................................... 3
GC-32 COMMAND SET ............................................................... 4
CONFIGURATION WEB PAGES................................................... 8
CONNECTORS- GPI, GPO ........................................................ 10
CONFIGURE GPIS FOR DRY/WET OPERATION ........................ 12
CONFIGURE GPOS FOR DRY/WET OPERATION ....................... 13
LIMITED WARRANTY .............................................................. 14
OVERVIEW
The GC-32 controls 32 individual GPOs (relay contact closure outputs) and monitors 32
individual GPIs (opto isolated inputs).
Upon receipt of a GPO control command the GC-32 will turn on or off the specified GPO,
or turn all GPOs on or off as specified within the command. The GPO command also
details the time that the GPO will stay on. A time of zero (0) will latch the GPO on. Any
other time 1 – 255 (x 10ms) will cause the GPO to turn off when the specified time in the
command elapses.
A GPI change of state notification will be sent automatically when a GPI change of state
is detected. The notification may include one or more GPIs and will contain the affected
GPI and its current state. The GPI state is communicated by an incrementing count. An
even count indicates that the GPI is off. An odd count indicates that t GPI is on. The
count will wrap from its maximum value to zero. If a client is not connected, GPI
notifications for that connection will be discarded.
The GC-32 is configured as a server and the 3
rd
party application is the client. The client
will establish a TCP/IP connection to port 50001 or 50002 to control and monitor the GC-
12843 Foothill Blvd. Suite C
Sylmar, California 91342
V: 818.898.3380
F: 818.898.3360
www.dnfcontrols.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 13 14

Shrnutí obsahu

Strany 1 - Programming Manual

Page 1 of 14 GC-32 GPIO CONTROLLER Programming Manual Revision History 05/09/12 First release 07/26/12 Added Table of Contents and product front

Strany 2

Page 10 of 14 CONNECTORS- GPI, GPO GPIO CONNECTORS: 4 x 37-Pin Female (D37F) GPI 1 – 16, GPI 17 – 32, GPO 1 – 16, GPO 17 - 32 GPI: Opto Isolated

Strany 3 - PROTOCOL DESCRIPTION

Page 11 of 14 A. GPI Connector Pin # Function Pin # Function 1 Ground 20 Ground 2 GPI #1 Anode (+) 21 GPI #1 Cathode (-) 3 GPI #2 Anod

Strany 4 - GC-32 COMMAND SET

Page 12 of 14 CONFIGURE GPIS FOR DRY/WET OPERATION GPIs are set to Dry operation by default. The GPIs may be set for Wet mode using either a Breakout

Strany 5 - Page 5 of 14

Page 13 of 14 CONFIGURE GPOS FOR DRY/WET OPERATION Note: Signal connected to Common Bus is isolated from the GC-32 electronics & power supply.

Strany 6 - Page 6 of 14

Page 14 of 14 LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one

Strany 7 - Page 7 of 14

Page 2 of 14 32 GPOs and GPIs. The client is responsible for establishing and maintaining the connection. In the event of a loss of connection, the

Strany 8 - CONFIGURATION WEB PAGES

Page 3 of 14 PROTOCOL DESCRIPTION The GC-32 command consists of the following components: Header + command + data NOTE- The “+” is used for read

Strany 9 - Page 9 of 14

Page 4 of 14 GC-32 COMMAND SET Set Operating Mode (Supported on port 50001 and 50002) Command= 0x30 Data: 0= Select Mode 1 GPOs 1 – 32 and GPIs 1-

Strany 10 - CONNECTORS- GPI, GPO

Page 5 of 14 GPO Control, All GPOs Command= 0x61 Data: 0x01 GPO State 0x00= OFF 0x01=

Strany 11 - Page 11 of 14

Page 6 of 14 GPI Control, Single GPI Command= 0x40 Data: GPI# 0x01 through 0x20 GPI Debounce 0x00 – 0xFF (Internally, debounce ti

Strany 12 - Page 12 of 14

Page 7 of 14 GPI Status, All GPIs Request status for all GPIs Command= 0x51 Data: 0x01 The GC-32 will respond with 44.4E.46.51.cc.gg1.ss1.gg2.ss2…..

Strany 13 - Page 13 of 14

Page 8 of 14 CONFIGURATION WEB PAGES Use a standard web-browser to access the GC-32’s web pages. Click on the GPI Events link to view the current sta

Strany 14 - LIMITED WARRANTY

Page 9 of 14 Click on the Remote Device Assignment link to view the IP address that is permitted to connect on ports 50001 and 50002. If the IP addr